VESSEL |
Total Volume |
30Liters |
30Liters |
Working Volume |
21Liters |
21Liters |
Construction |
> Aspect Ratio:2:1 > Code Ratings:ASME/CE > Vessel Access:Headplate
> Material of construction:316L SS > Vessel Pressure 40 PSIG,Full Vacuum > Finish:15Ra electropolished interior[standard] |
Agitation |
Drive:Top drive,Double-mechanical seal |
Speed |
100-800RPM |
100-700RPM |
Impellers |
(2)Rushton-Style impellers |
Baffles |
Standard:(4)Removable,316 L stainless-steel.Optional:Baffle plug kit |
PORTS |
Headplate |
> (4)PG13.5 [light, Level 1 sensor/spare, Level 2 sensor/spare, septum/spare]
> (4)1.5 in NBS connect sanitary style [pressure transducer/spare, exhaust, and (2) spray balls/septums/spares] |
Upper side wall |
> (7) 1.5 in NBS connect sanitary style [gas overlay/spare, vessel rupture device, and (4) addition valves/spares]
> (1) 3 in NBS connect sanitary style [vessel sight glass] |
Lower side wall |
> (7) 1.5 in NBS connect sanitary style [RTD, sample/spare, pressure guage/spare, sparger/spare, and (3) DO/pH/Redox or combinations thereof] |
Bottom |
(1) 1.5 in NBS connect sanitary style [radial diaphragm drain valve] |
CONTROLLER |
Control station |
Controls one vessel with 32 control loops. Stores 10 recipes and eight process variables for trend graphing.Includes an industrial touchscreen monitor/user interface, three built-in pumps, and connections for all utilities and communication signals |
Touchscreen
interface/display |
38 cm (15 in) Industrial touchscreen interface/display |
PUMPS |
Standard, options & control |
Standard: Three built-in, assignable, peristaltic pumps. Control modes: Off, Prime, Base, Acid, Foam, Level 2 Wet, Level 2 Dry, Volume Add, Volume Harvest
Optional: Two external variable-speed pumps can be added |
Speed |
Pumps 1, 2 and 3: 100 rpm Fixed-speed duty cycle, ability to view total pump flow rates |
PIPING SKID |
Construction |
> Material of construction: 316L stainless steel
> Gaskets/O-Rings: Class (VI) EPDM and Silicon |
Aeration |
Standard: 1 Thermal Mass Flow Controller (TMFC) with flow rates up to 2 VVM and built in four-gas control (4 solenoid valves) Optional: Rotameter or 2nd, 3rd, or 4th TMFCs for individual gas control) |
Gas inlet |
Sparger/overlay filter housing with 0.2 µ absolute disposal filter. Overlay valve optional |
Exhaust line |
Standard: Line designed for minimal backpressure. Includes heater and 1.2 µ nominal exhaust filter and housing, with manual backpressure regulator
Optional: Automatic backpressure control |
Temperature control line
|
> All systems come with automatic sterilization program
>Operating temperature control range 10 °C above water supply temperature to 80 °C
> Line designed to achieve 1 °C/minute temperature rises, in the 30 °C - 50 °C range
> Optional: Glycol/chiller heat exchanger designed to remove 100 watts/L |
Load cell |
Provided for measuring vessel volume |
SENSOR |
Options |
> pH/DO sensor kits
> Redundant pH/DO sensor kits
> Redox sensor kit |
DIMENSIONS |
(W x D x H) |
116 x 86 x 151 cm (45.5 x 34.0 x 59.5 in) |
ADDITIONAL OPTIONS |
> Spray balls > Foam/level kits > Turbidity sensor/transmitter
> Utility prefilter/regulator kit > Transfer lines > Sterile sampling kit
> Addition vessels > Marine and pitched-blade impellers
> 1 or 7 port septum > Mobile headplate lift > Scales for addition vessel
> Validation packages > Additional sight glass > Vessel passivation |
REQUIREMENTS
&CONNECTIONS
UTILITY |
Process air/gases
O2, N2, CO2 |
30 PSIG , 32 SLPM
|
30 PSIG , 64 SLPM
|
Instrument air |
80-100 PSIG , 2 scfm (56.5 SLPM) |
Process steam |
35 PSIG, 10 lb/hr |
Utility steam |
35 PSIG , 30 lb/hr |
35 PSIG, 35 lb/hr |
Facility water |
30PSIG,1 gpm |
Water return |
Less than 15 PSIG back pressure |
Clean condensate |
Gravity drain |
Biowaste |
Gravity drain |
Glycol/chiller |
30PSIG 1 GPM |
30PGIG 2 GPM |
Electric |
208-230 V AC, single phase, 50/60 Hz, 20 A |
INPUT/OUTPUT
CONNECTIONS
&
COMM PORTS
(Built into the back panel of Master Control Station) |
External Devices |
Seven analog inputs and seven analog outputs for your external devices such as analyzers, sensors, external pumps, etc. (Reduce by 1 input & output for each additional TMFC added) |
2 USB Ports |
Import firmware/software upgrades and export
trend data. Connect an optional 8-port serial box for accessories requiring serial connections |
Comm. Port |
For optional BioCommand/SCADA software |